toplogo
سجل دخولك
رؤى - Functional MRI Registration - # Slice-to-Volume Registration

A Self-Attention Model for Robust Rigid Slice-to-Volume Registration of Functional MRI


المفاهيم الأساسية
A self-attention based deep learning model for aligning 2D functional MRI slices with a 3D reference volume, improving robustness against input data variations and uncertainties.
الملخص

The content discusses a novel end-to-end slice-to-volume registration (SVR) model for aligning 2D functional MRI (fMRI) slices with a 3D reference volume. The key highlights are:

  • Functional MRI is vital for neuroscience research and clinical practice, but head motion during scans can lead to distortion and biased analyses. Retrospective slice-level motion correction through SVR is crucial.

  • Previous deep learning-based SVR methods overlooked the uncertainty stemming from the input stack of slices and did not assign weighting or scoring to each slice.

  • The proposed Self-Attention SVR (SA-SVR) model incorporates a self-attention mechanism to enhance robustness against input data variations and uncertainties. It uses independent slice and volume encoders, and a self-attention module to assign pixel-wise scores for each slice.

  • Experiments on synthetic rigid motion generated from the Healthy Brain Network dataset show that SA-SVR achieves competitive performance in alignment accuracy compared to state-of-the-art methods, and significantly faster registration speed compared to conventional iterative methods.

  • The end-to-end SVR model facilitates real-time head motion tracking during fMRI acquisition, ensuring reliability and robustness against uncertainties in inputs.

edit_icon

تخصيص الملخص

edit_icon

إعادة الكتابة بالذكاء الاصطناعي

edit_icon

إنشاء الاستشهادات

translate_icon

ترجمة المصدر

visual_icon

إنشاء خريطة ذهنية

visit_icon

زيارة المصدر

الإحصائيات
Head motion can increase scan times and associated costs by over 57% in resting state fMRI. A substantial portion of fMRI data was rendered unusable due to motion, specifically when frame displacement exceeded 0.2mm.
اقتباسات
"Functional Magnetic Resonance Imaging (fMRI) is vital in neuroscience, enabling investigations into brain disorders, treatment monitoring, and brain function mapping." "Head motion can occur at any time during the different shots of the slices acquisition of fMRI, making it susceptible to slice-level, or intra-volume, motion artifacts."

الرؤى الأساسية المستخلصة من

by Samah Khawal... في arxiv.org 04-09-2024

https://arxiv.org/pdf/2404.04546.pdf
A self-attention model for robust rigid slice-to-volume registration of  functional MRI

استفسارات أعمق

How can the proposed self-attention mechanism be extended to handle non-rigid motion in fMRI scans?

The self-attention mechanism proposed in the context for slice-to-volume registration (SVR) can be extended to handle non-rigid motion in fMRI scans by incorporating additional layers or modules in the neural network architecture. Non-rigid motion in fMRI scans involves deformations and distortions that go beyond simple translations and rotations. To address this, the self-attention mechanism can be enhanced to capture spatial relationships and dependencies across the slices and volumes more effectively. One approach could involve integrating spatial transformers or deformable convolutional layers into the network. These components can learn to deform the input slices adaptively based on the motion present in the data. By allowing the network to learn non-linear transformations, it can better align the 2D slices with the 3D volume, even in the presence of complex non-rigid motion patterns. Additionally, introducing spatial regularization techniques, such as spatial dropout or spatial batch normalization, can help the network generalize better to non-rigid motion scenarios. These techniques can encourage the model to focus on relevant spatial features and reduce overfitting to rigid transformations.

What are the potential limitations of using synthetic motion data for training and evaluating the SVR model, and how could real-world motion data be incorporated?

Using synthetic motion data for training and evaluating the SVR model may have limitations in capturing the full complexity and variability of real-world motion patterns observed in fMRI scans. Synthetic motion data may not fully represent the diversity of motion artifacts and distortions present in actual clinical or research fMRI datasets. Additionally, the synthetic motion parameters used for generating the data may not perfectly mimic the nuances of real patient motion. To address these limitations and incorporate real-world motion data, one approach is to collect fMRI scans from actual patients or participants exhibiting a range of motion patterns. These scans can then be annotated with ground truth motion parameters, either through manual labeling or automated motion tracking algorithms. By using real-world data, the SVR model can learn from the variability and complexity of motion artifacts encountered in practice. Furthermore, data augmentation techniques can be applied to introduce variability in the training data, simulating different motion scenarios and enhancing the model's robustness to unseen motion patterns. Augmentation methods such as random rotations, translations, and deformations can help the model generalize better to diverse motion patterns present in real fMRI scans.
0
star