toplogo
Log på

BRAU-Net: A Novel Deep Learning Approach for Pubic Symphysis-Fetal Head Segmentation in Transperineal Ultrasound Images


Kernekoncepter
This paper introduces BRAU-Net, a novel deep learning architecture that leverages a dynamic sparse attention mechanism and an inverted bottleneck patch expanding module to achieve state-of-the-art results in pubic symphysis-fetal head segmentation on transperineal ultrasound images.
Resumé

Bibliographic Information:

Cai, P., Jiang, L., Li, Y., Liu, X., & Lan, L. (2024). Pubic Symphysis-Fetal Head Segmentation Network Using BiFormer Attention Mechanism and Multipath Dilated Convolution. arXiv preprint arXiv:2410.10352.

Research Objective:

This paper proposes a novel deep learning model, BRAU-Net, to address the challenges of automatic pubic symphysis (PS) and fetal head (FH) segmentation in transperineal ultrasound (TPU) images, aiming to improve the accuracy and efficiency of fetal descent assessment during labor.

Methodology:

The authors developed BRAU-Net, a U-Net-like encoder-decoder architecture incorporating:

  • BiFormer blocks: These blocks utilize a bi-level routing attention mechanism to effectively capture both local and global semantic information while maintaining computational efficiency.
  • Inverted Bottleneck Patch Expanding (IBPE) module: This module is designed to mitigate information loss during upsampling, enhancing the model's ability to preserve fine-grained details crucial for accurate segmentation.
  • Skip connections: Similar to the original U-Net, skip connections are employed to bridge the encoder and decoder pathways, facilitating the fusion of multi-scale features and further improving segmentation accuracy.

Key Findings:

  • BRAU-Net outperforms existing state-of-the-art methods in PS-FH segmentation on two benchmark datasets: FH-PS-AoP and HC18.
  • The proposed model demonstrates superior performance in terms of Dice Similarity Coefficient (DSC), Hausdorff Distance (HD), and Average Surface Distance (ASD) compared to traditional CNN-based methods and hybrid CNN-Transformer models.
  • Ablation studies confirm the effectiveness of the BiFormer block and the IBPE module in enhancing segmentation accuracy.

Main Conclusions:

  • BRAU-Net presents a significant advancement in automated PS-FH segmentation for TPU images, demonstrating the potential to improve fetal descent assessment and potentially reduce delivery risks.
  • The integration of dynamic sparse attention mechanisms and the IBPE module proves beneficial for capturing long-range dependencies and preserving fine-grained details in medical image segmentation tasks.

Significance:

This research contributes to the field of medical image analysis by introducing a novel deep learning architecture specifically designed for accurate and efficient PS-FH segmentation in TPU images. The proposed BRAU-Net model has the potential to assist clinicians in making more informed decisions during labor, ultimately contributing to improved maternal and fetal outcomes.

Limitations and Future Research:

  • The study primarily focuses on 2D ultrasound images. Further research could explore the extension of BRAU-Net to 3D ultrasound data for a more comprehensive assessment of fetal descent.
  • Investigating the generalizability of BRAU-Net to other challenging medical image segmentation tasks could further validate its effectiveness and broader applicability.
edit_icon

Tilpas resumé

edit_icon

Genskriv med AI

edit_icon

Generer citater

translate_icon

Oversæt kilde

visual_icon

Generer mindmap

visit_icon

Besøg kilde

Statistik
The FH-PS-AoP dataset consists of 4000 training and 1101 testing samples. The HC18 dataset consists of 999 training and 355 testing samples. BRAU-Net achieves a DSC of 90.20% and 91.04% on FH and PS respectively for the FH-PS-AoP dataset. BRAU-Net achieves a DSC of 94.18% for the HC18 dataset. BRAU-Net has 38.78M parameters and performs 36.71 GFLOPs.
Citater
"Manual segmentation of the pubis symphysis (PS) and fetal head (FH) from intrauterine (ITU) images is currently considered as the most dependable method (see Fig. 1 for a segmentation case), but it is exceptionally time-consuming and susceptible to subjectivity [3]." "However, the sparse transformers used by these methods are manually designed and static, which leads to large differences on segmentation performance among specific datasets." "Our result in the PSFHS challenge 1 verifies that our model has excellent segmentation performance on FH-PS-AoP dataset."

Dybere Forespørgsler

How might the integration of other imaging modalities, such as MRI or 3D ultrasound, further enhance the accuracy and clinical utility of BRAU-Net for fetal descent assessment?

Integrating other imaging modalities like MRI or 3D ultrasound could significantly enhance BRAU-Net's accuracy and clinical utility for fetal descent assessment in several ways: Improved Soft Tissue Contrast: MRI offers superior soft tissue contrast compared to 2D ultrasound, allowing for a clearer delineation of the fetal head, pubic symphysis, and surrounding structures like the bladder and cervix. This enhanced visualization could lead to more precise segmentation, especially in cases where ultrasound images suffer from artifacts or poor image quality. Three-Dimensional Anatomical Information: 3D ultrasound and MRI provide volumetric data, enabling the reconstruction of the fetal head and maternal pelvis in three dimensions. This 3D context facilitates a more comprehensive understanding of spatial relationships and fetal head positioning within the birth canal, potentially leading to more accurate angle of progression (AoP) measurements and a better prediction of labor progression. Multimodal Fusion for Robustness: Combining information from different modalities can improve the robustness and accuracy of the segmentation model. By fusing data from 2D ultrasound, 3D ultrasound, and/or MRI, BRAU-Net could leverage the strengths of each modality while compensating for their individual limitations. This multimodal approach could lead to a more reliable and generalizable solution for fetal descent assessment. Enhanced Clinical Decision Support: The richer information derived from multimodal imaging could be used to develop more sophisticated clinical decision support systems. These systems could assist healthcare providers in making more informed decisions regarding labor management, interventions, and potential complications associated with fetal descent. However, integrating additional modalities also presents challenges: Data Acquisition and Registration: Acquiring and registering images from different modalities can be technically challenging and time-consuming. Computational Complexity: Processing and analyzing multimodal data requires more computational resources and sophisticated algorithms. Increased Costs: Incorporating MRI or 3D ultrasound into routine clinical workflows may increase costs. Despite these challenges, the potential benefits of multimodal imaging for fetal descent assessment are significant. Future research should focus on developing efficient and robust methods for multimodal image acquisition, registration, and fusion, as well as evaluating the clinical impact of such integrated approaches.

Could the reliance on pre-trained weights potentially introduce biases related to the specific dataset used for pre-training, and how can these biases be mitigated?

Yes, relying on pre-trained weights can introduce biases related to the dataset used for pre-training. This is particularly relevant in medical imaging, where datasets often exhibit specific characteristics: Dataset Bias: If the pre-training dataset primarily consists of images from a specific population (e.g., certain ethnicities, age groups) or acquired using particular ultrasound machines or settings, the model might not generalize well to images from other populations or acquired under different conditions. This can lead to inaccurate segmentations and potentially biased clinical decisions. Here's how to mitigate these biases: Diverse Pre-training Datasets: Utilize pre-trained weights from models trained on large and diverse datasets that encompass a wide range of patient demographics, ultrasound equipment, and imaging conditions. This helps ensure the model is exposed to a broader spectrum of variations and reduces the risk of bias towards specific characteristics. Fine-tuning with Target Data: Thoroughly fine-tune the pre-trained model using a substantial dataset representative of the target population and imaging setup. This adaptation process allows the model to adjust its learned representations and specialize in the specific characteristics of the fetal descent assessment task and the relevant patient population. Data Augmentation: Employ extensive data augmentation techniques during both pre-training and fine-tuning to artificially increase the diversity of the training data. This includes transformations like rotations, scaling, brightness adjustments, and adding noise, which can help the model learn more robust and generalizable features. Bias Detection and Correction: Implement techniques to detect and correct for potential biases in the model's predictions. This can involve analyzing the model's performance across different subgroups of the target population and adjusting the training process or decision thresholds to mitigate disparities. Transparency and Validation: Clearly document the pre-training dataset and any potential limitations or biases. Rigorously validate the model's performance on independent and diverse datasets to ensure its generalizability and fairness. Addressing bias in medical image analysis is crucial for ensuring equitable and reliable healthcare. By carefully considering the pre-training dataset, employing appropriate mitigation strategies, and prioritizing transparency and rigorous validation, developers can create more robust and fair AI models for fetal descent assessment and other medical applications.

What are the ethical considerations surrounding the increasing automation of medical image analysis, particularly in the context of labor and delivery, and how can these concerns be addressed responsibly?

The increasing automation of medical image analysis, especially in sensitive areas like labor and delivery, raises several ethical considerations: Informed Consent and Patient Autonomy: Ensuring informed consent becomes crucial when AI systems are involved in clinical decision-making. Patients must be adequately informed about the use of AI, its potential benefits and limitations, and their right to decline AI-assisted analysis or seek a second opinion. Algorithmic Bias and Health Disparities: As mentioned earlier, biases in training data can perpetuate existing health disparities. It's essential to proactively address algorithmic bias by using diverse datasets, implementing bias detection and mitigation techniques, and ensuring equitable access to these technologies. Data Privacy and Security: Labor and delivery involve highly sensitive patient information. Robust data protection measures, including de-identification, secure storage, and access control, are paramount to maintain patient privacy and confidentiality. Over-reliance and Deskilling: While AI can assist healthcare providers, it's crucial to avoid over-reliance that could lead to deskilling. Maintaining clinical expertise and critical thinking is essential to interpret AI outputs, recognize potential errors, and make informed decisions in complex situations. Transparency and Explainability: Black-box AI systems can erode trust and hinder accountability. Striving for transparency in algorithms and providing understandable explanations for AI-driven recommendations is crucial for both patients and healthcare providers. Unintended Consequences and Responsibility: Thoroughly considering the potential unintended consequences of AI implementation is vital. Establishing clear lines of responsibility and accountability for AI-driven decisions, especially in case of errors or adverse events, is crucial. Addressing these concerns requires a multi-faceted approach: Ethical Frameworks and Guidelines: Developing and adhering to ethical guidelines specific to AI in healthcare, particularly in sensitive areas like labor and delivery, is essential. Regulatory Oversight and Standards: Establishing regulatory frameworks and standards for developing, deploying, and monitoring AI-based medical devices can ensure safety, efficacy, and ethical considerations are met. Interdisciplinary Collaboration: Fostering collaboration between clinicians, data scientists, ethicists, and patients is crucial throughout the entire AI lifecycle, from design and development to implementation and evaluation. Continuous Monitoring and Evaluation: Regularly monitoring AI systems for bias, accuracy, and unintended consequences is essential. Implementing mechanisms for feedback and continuous improvement can help ensure responsible and ethical use. Education and Training: Educating healthcare providers about AI's capabilities, limitations, and ethical implications is crucial. Similarly, empowering patients with knowledge about AI in healthcare can facilitate informed decision-making. By proactively addressing these ethical considerations, we can harness the potential of AI in labor and delivery to improve patient care while upholding the highest ethical standards and ensuring equitable and trustworthy healthcare for all.
0