toplogo
Connexion
Idée - Medical image processing - # Deformable Image Registration for Abdominal MRI-CT Alignment

Diffeomorphic Transformer-based Deformable Image Registration for Abdominal MRI-CT Alignment


Concepts de base
A novel deep learning-based method that utilizes a diffeomorphic transformer model to accurately estimate a deformation vector field for aligning abdominal MRI and CT images.
Résumé

The content describes the development of a deep learning-based deformable image registration (DIR) method for aligning abdominal MRI and CT images. The proposed method assumes diffeomorphic deformations and leverages topology-preserved deformation features extracted from a probabilistic diffeomorphic registration model to accurately capture abdominal motion and estimate the deformation vector field (DVF). To enhance the deformable feature extraction, the method integrates Swin transformers, which have shown excellent performance in motion tracking, into a convolutional neural network (CNN)-based model.

The model is optimized using a combination of volume-based similarity for unsupervised training and surface matching for semi-supervised training. This dual optimization approach ensures that the generated DVF not only aligns the volumes but also matches the surfaces with a particular focus on organs-at-risk (OARs).

The performance of the proposed method is evaluated on a dataset of 50 liver cancer patients who underwent radiotherapy. Compared to rigid registration and other state-of-the-art deep learning-based DIR methods, the proposed method demonstrates significant improvements in target registration error, Dice similarity coefficient for the liver and portal vein, and mean surface distance of the liver. The incorporation of the Swin transformer is also shown to improve the registration accuracy compared to the CNN-based model without the transformer.

edit_icon

Personnaliser le résumé

edit_icon

Réécrire avec l'IA

edit_icon

Générer des citations

translate_icon

Traduire la source

visual_icon

Générer une carte mentale

visit_icon

Voir la source

Stats
The mean Dice similarity coefficient (DSC) values of the liver and portal vein increased from 0.850±0.102 and 0.628±0.129 to 0.903±0.044 and 0.763±0.073 after deformable image registration (DIR) using the proposed method. The mean target registration error (TRE) decreased from 26.238±2.769 mm to 8.492±1.058 mm after DIR using the proposed method. The mean surface distance (MSD) of the liver decreased from 7.216±4.513 mm to 3.232±1.483 mm after DIR using the proposed method.
Citations
"The proposed DIR method based on a diffeomorphic transformer provides an effective and efficient way to generate an accurate DVF from an MRI-CT image pair of the abdomen. It could be utilized in the current treatment planning workflow for liver SBRT." "When compared to only rigid registration, DIR with the proposed method resulted in an increase of the mean DSC values of the liver and portal vein from 0.850±0.102 and 0.628±0.129 to 0.903±0.044 and 0.763±0.073, a decrease of the mean MSD of the liver from 7.216±4.513 mm to 3.232±1.483 mm, and a decrease of the TRE from 26.238±2.769 mm to 8.492±1.058 mm."

Questions plus approfondies

How can the proposed method be extended to handle a wider range of MRI modalities beyond T1-weighted FSPGR scans?

The proposed method can be extended to handle a wider range of MRI modalities by incorporating a more diverse training dataset that includes various MRI sequences commonly used in clinical practice. This would involve training the model on different MRI modalities such as T2-weighted, diffusion-weighted imaging, and contrast-enhanced sequences. By exposing the model to a broader range of MRI modalities during training, it can learn to adapt to the different intensity distributions and structural features present in each modality. Additionally, the inclusion of data augmentation techniques can help simulate variations in MRI modalities, enhancing the model's ability to generalize to unseen data. Techniques such as intensity normalization, geometric transformations, and adding noise to the images can help the model learn robust features that are applicable across different MRI modalities. Furthermore, transfer learning from pre-trained models on diverse MRI datasets can also be beneficial. By leveraging knowledge learned from pre-trained models on various MRI modalities, the proposed method can improve its performance when handling new modalities. Fine-tuning the model on specific MRI sequences of interest can help adapt the model to the unique characteristics of each modality.

What are the potential limitations of using surface matching loss in the semi-supervised training, and how can they be addressed?

One potential limitation of using surface matching loss in semi-supervised training is the sensitivity to inaccuracies in the manual delineation of structures on MRI and CT images. Manual contouring can introduce variability and errors, leading to discrepancies in the surface matching process. This can result in suboptimal deformable image registration and inaccurate alignment of structures between modalities. To address this limitation, automated segmentation techniques can be employed to generate more precise and consistent contours for training the model. Utilizing deep learning-based segmentation algorithms can help improve the accuracy and reliability of the delineated structures, reducing the impact of manual errors on the surface matching loss. Another approach to mitigate the limitations of surface matching loss is to incorporate additional regularization techniques during training. By introducing constraints that encourage smoothness and consistency in the deformation field, the model can learn to produce more realistic and anatomically plausible registrations. Regularization methods such as total variation regularization or landmark-based constraints can help improve the robustness of the surface matching loss in the semi-supervised training process.

What other deep learning architectures or techniques could be explored to further improve the deformable registration accuracy for abdominal MRI-CT alignment?

Several deep learning architectures and techniques can be explored to enhance deformable registration accuracy for abdominal MRI-CT alignment. One approach is to investigate the use of attention mechanisms in the network architecture. Attention mechanisms can help the model focus on relevant image regions during the registration process, improving the alignment of anatomical structures and enhancing the overall accuracy of the registration. Another technique to consider is the integration of generative adversarial networks (GANs) for data augmentation and regularization. GANs can generate synthetic MRI-CT image pairs, providing additional training data to improve the model's generalization capabilities. By incorporating GANs into the training pipeline, the model can learn more robust features and improve its performance on unseen data. Furthermore, exploring multi-scale and multi-resolution strategies in the network design can help capture both global and local deformations in the images. Hierarchical architectures that process images at different scales can improve the model's ability to handle variations in anatomical structures and deformations, leading to more accurate registrations. Additionally, leveraging self-supervised learning techniques, such as contrastive learning or pretext tasks, can help the model learn meaningful representations from the input data without requiring manual annotations. By pretraining the model on self-supervised tasks, it can acquire better feature representations and improve its performance on deformable image registration tasks.
0
star