The study compared stress calculations in abdominal aortic aneurysms (AAAs) using semi-automated and AI-based segmentations. The AI method led to slightly higher peak and 99th percentile maximum principal stress values due to larger lumen surfaces. Despite differences in stress magnitudes, the distribution patterns remained similar across both segmentation methods. The study highlights the importance of accurate lumen boundary determination, often underestimated in literature.