Основные понятия
The study compares semi-automated and AI-based segmentation methods for AAA biomechanical analysis, revealing slightly higher stress values with AI segmentation due to larger lumen surface areas.
Аннотация
The study compared stress calculations in abdominal aortic aneurysms (AAAs) using semi-automated and AI-based segmentations. The AI method led to slightly higher peak and 99th percentile maximum principal stress values due to larger lumen surfaces. Despite differences in stress magnitudes, the distribution patterns remained similar across both segmentation methods. The study highlights the importance of accurate lumen boundary determination, often underestimated in literature.
Статистика
Ten different AAA contrast-enhanced CT images were segmented semi-automatically by an analyst.
Automated neural network-based segmentation required only 1-2 minutes per patient.
Eight out of ten cases showed higher maximum principal stress values with automatic segmentation.
Tetrahedral finite element meshes varied between 520,000 - 920,000 elements depending on the patient-specific aneurysm.
Relative difference in number of elements between semi-automatic and automatic segmentations ranged from -13% to +15%.