Mitigating Data Consistency Induced Discrepancy in Cascaded Diffusion Models for Sparse-view CT Reconstruction


Khái niệm cốt lõi
Addressing data consistency discrepancy in sparse-view CT reconstruction using a cascaded diffusion model with discrepancy mitigation.
Tóm tắt

Sparse-view CT reconstruction poses challenges due to image degradation. The study introduces a Cascaded Diffusion with Discrepancy Mitigation (CDDM) framework to address this issue. By generating low-quality images in latent space and high-quality images in pixel space, the framework minimizes computational costs and mitigates the training-sampling gap induced by data consistency. Specialized Alternating Direction Method of Multipliers (ADMM) is employed for image gradients, enhancing regularization. Experimental results demonstrate CDDM's superior performance in high-quality image generation compared to existing methods.

edit_icon

Tùy Chỉnh Tóm Tắt

edit_icon

Viết Lại Với AI

edit_icon

Tạo Trích Dẫn

translate_icon

Dịch Nguồn

visual_icon

Tạo sơ đồ tư duy

visit_icon

Xem Nguồn

Thống kê
Sparse-view Computed Tomography (CT) image reconstruction reduces radiation exposure. Diffusion model-based approaches provide a potential solution but suffer from training-sampling discrepancy. CDDM framework minimizes computational costs by moving inference steps from pixel space to latent space. Specialized ADMM processes image gradients separately for better regularization. Experimental results show CDDM outperforms existing methods in high-quality image generation.
Trích dẫn

Thông tin chi tiết chính được chắt lọc từ

by Hanyu Chen,Z... lúc arxiv.org 03-15-2024

https://arxiv.org/pdf/2403.09355.pdf
Mitigating Data Consistency Induced Discrepancy in Cascaded Diffusion  Models for Sparse-view CT Reconstruction

Yêu cầu sâu hơn

How can the DM process be optimized to reduce computational costs further

To optimize the DM process and reduce computational costs further, several strategies can be implemented: Batch Processing: Implementing batch processing techniques can help in parallelizing computations and reducing overall processing time. By processing multiple images simultaneously, the computational load can be distributed efficiently. Optimized Network Architecture: Fine-tuning the network architecture used in the DM process can lead to more efficient computations. Utilizing lightweight architectures or optimizing existing ones through techniques like model pruning or quantization can help reduce computational complexity. Hardware Acceleration: Leveraging hardware accelerators such as GPUs or TPUs can significantly speed up computations for the DM process. These specialized hardware devices are designed to handle complex mathematical operations efficiently, leading to faster processing times. Algorithmic Optimization: Refining the algorithms used in the DM process by streamlining calculations, reducing redundant operations, and optimizing memory usage can contribute to lowering computational costs while maintaining performance levels. Data Preprocessing Techniques: Employing data preprocessing methods like dimensionality reduction or feature extraction before feeding data into the DM model can help reduce input dimensions and computation requirements without compromising on accuracy.

What are the implications of applying the CDDM framework to other medical imaging challenges

Applying the CDDM framework to other medical imaging challenges could have several implications: Improved Image Quality: The CDDM framework's ability to mitigate training-sampling discrepancies could enhance image quality in various medical imaging tasks such as MRI reconstruction, ultrasound imaging enhancement, or PET scan reconstruction. Faster Reconstruction Times: By leveraging a two-stage approach with latent diffusion models followed by pixel space diffusion models, CDDM could potentially accelerate image reconstruction processes for different modalities of medical imaging. Enhanced Diagnostic Accuracy: Higher-quality images generated through CDDM may lead to improved diagnostic accuracy by providing clearer details and better-defined boundaries of anatomical structures in medical scans. Reduced Radiation Exposure: In scenarios where sparse-view reconstructions are utilized for reducing radiation exposure during CT scans or X-ray imaging procedures, applying CDDM could maintain image quality while minimizing radiation dose levels.

How does the specialized ADMM method compare to standard ADMM in other inverse problems

Comparing specialized ADMM with standard ADMM in other inverse problems reveals some key differences: Specialized ADMM is tailored specifically for problems involving gradients in different directions separately (such as TV regularization), making it more suitable for multidimensional total-variation regularization tasks compared to standard ADMM. 2.. Standard ADMM is more general-purpose and widely applicable across a range of optimization problems but may not offer the same level of efficiency when dealing with specific directional constraints present in certain inverse problems. 3.. In scenarios where decomposition of gradient terms is crucial for problem-solving efficacy (as seen in specialized cases like 3D CT image reconstruction), specialized ADMM outperforms standard ADMM due to its targeted approach towards handling gradients separately. 4.. For applications requiring intricate control over individual components within an optimization problem (like separate treatment of xy-plane vs z-direction gradients), specialized ADMM provides a more nuanced solution that leads to enhanced results compared to standard approaches that treat all components uniformly.