核心概念
A new HASEL actuator design and compact sensing circuitry enable accurate displacement estimation during high-frequency actuation and external loading using miniaturized components.
摘要
The paper introduces the F-HASEL actuator, which features an additional electrode pair used exclusively for capacitive sensing, separating sensing from actuation. Two compact sensing circuit designs using low-cost off-the-shelf components are proposed to estimate the F-HASEL's displacement.
The experiments demonstrate the capability of the circuits to accurately estimate the displacement during high-frequency actuation up to 20 Hz and external loading using a miniature high-voltage power supply. The sensing methods are also shown to be agnostic to the driving voltage polarity, enabling the mitigation of charge retention effects.
Furthermore, a circuitry is proposed to enable quasi-simultaneous displacement estimation of multiple F-HASELs, which is demonstrated in a wearable virtual reality application that tracks the knee and hip joint rotations of a user in real-time.
The key highlights include:
- Introduction of the F-HASEL actuator design with dedicated sensing electrodes
- Two compact sensing circuit designs using low-cost off-the-shelf components
- Accurate displacement estimation during high-frequency actuation up to 20 Hz
- Displacement estimation under external loading using miniature power supplies
- Polarity-agnostic sensing enabling mitigation of charge retention effects
- Quasi-simultaneous displacement estimation of multiple F-HASELs
- Demonstration of a wearable VR application tracking joint rotations in real-time
統計資料
The experiments show a reduction in noise magnitude of around 17 times on the voltage measurement across the F-HASEL's sensing electrodes compared to previous methods.
The voltage-based sensing method achieves a normalized root mean squared error (NRMSE) of 0.0302 at 1 Hz and 0.0524 at 5 Hz actuation, a significant improvement over the previous state-of-the-art.
At 8 Hz actuation, the voltage-based method has an NRMSE of 0.0638, while the impedance-based method has an NRMSE of 0.0589.
引述
"The reduction in noise across the LV sensing electrodes, compared to the resistors (RK) and (RC), means that any sensing method based on measuring changes in the voltage (VH) will have a notably higher signal-to-noise ratio than methods measuring changes across measuring resistors (RC) or (RK), assuming the same LV signal is applied."
"Compared to the work of Ly et al. [5], which this paper considers the state-of-art in capacitive sensing of Peano-HASEL actuators, we see at 1 Hz a reduction from an NRMSE of approx. 0.1000 to 0.0302, and at 5 Hz a reduction from an NRMSE of approx. 0.8000 to 0.0524."